Picture signal CVBS

Recorded signal paths

The following signal path can deviate from the voltage values. The sequence should, however, match at the marked positions.

Signal path CVBS signal

GR_FBAS-DISPLUS

For the CVBS signal, the color information of the colors green, red and blue are transmitted across a single cable. The signal path has three important points that are independent of the image transmitted at that moment. This is why these can be used for measurement

For measurement, the following voltage differences must be examined.

Difference

With adapter

Without adapter

Point 1, Point 2

0.4 V

0.8 V

Point 2, Point 3

0.3 V

0.6 V

Measurement with and without adapter

In the case of measurement without adapter, the second Control module (SG2) is disconnected. Upper circuit. For this measurement, the signal level is only measured via the resistance R. This is why a measurement without adapter leads to a double signal level.

In the case of measurement with adapter, the second Control module (SG2) remains connected. The signal level is then measured via the parallel circuit of resistances R and R2. Lower circuit.

GR_MIT_OHNE_ADAPTER