A/C-capacity output DDE

The air-conditioning compressor is switched on and off by DDE control module via the A/C-compressor relay. The DDE control module receives a message from the heating and A/C control module as to whether the air conditioning system button is pressed and whether the heating and A/C control module is requesting that the compressor be switched on.

If a request is received to switch on the A/C compressor, the DDE control module checks whether conditions that do not permit the compressor to be switched on apply and sends a corresponding message back to the heating and air conditioning control module.

With the air-conditioning compressor switched on, the idling speed is increased.

Troubleshooting

The line between the DDE control module and the relay is monitored for open circuit and short circuit. Fault code ”A/C power output” is stored in the case of defect.