This functional description covers the air distribution of the IHS and of the IHKS.

Index |
Explanation |
1 |
Air-distribution control wheel |
Air distribution is carried out by the air distribution flap, which in turn is adjusted by the air distribution flap mechanical system. The mechanical system is driven by the air distribution flap motor.
The air distribution flap motor has no detection of its current position. For this reason, the flap motor must be activated depending on a reference position. This enables exact and reproducable positioning.
The reference position is an end position of the air distribution flap. Evaluation of the flap motor load current indicates the end position.
The reference run is carried with every ”power on reset”. It can also be triggered by the BMW diagnosis system.
The air distribution is set manually using the air-distribution control wheel. Depending on the set position, the air distribution flap motor moves the air distribution flap to the desired position.
Air distribution |
approximate position of the air distribution flap |
|---|---|
BOTTOM |
0 % |
top-bottom |
11 % |
Defrost |
28 % |
MIDDLE |
44 % |
top-centre-bottom |
72 % |
Observe the following information for service:
The temperature display can be switched to °C or °F using the on-board computer function.
No liability can be accepted for printing or other faults. Subject to changes of a technical nature