MOST bus: fiber-optic cable communication fault

The MOST (Media Oriented Systems Transport) network uses a ring bus for data communication between the various control modules. Signal transmission is by means of fiber-optic cable. Data transmission on the ring bus takes place in one direction only. On the MOST ring, messages can only be transmitted provided the bus ring is complete and fully functional. If there is a ring fault in the MOST network, however, the diagnosis system can only communicate with the instrument cluster and the Control Display. This is possible because those two control modules are directly connected to the K-CAN SYSTEM bus.

If, for example, the power supply or the diode of a control module is defective, it is no longer possible to communicate with the control modules on the MOST bus. Exceptions here are of course the instrument cluster and the Control Display.

Transmission direction in the MOST ring

Transmission of messages is from the Control Display towards the CD changer, antenna tuner, ..., instrument cluster, ... and back to the Control Display.

Control Display

The Control Display is divided into the functions CD GW Control Display (Gateway) and CD Control Display. The gateway is the interface between the MOST and K-CAN SYSTEM buses. For the remaining troubleshooting (read fault memory, etc.) of the Control Display, only the control module name CD GW Control Display (Gateway) needs to be selected at the tester!

Diagnosis MOST bus

For the MOST bus, there are intersystem fault memory entries in the control modules. A feature of the system faults is that they can be entered in a control module although the control module is OK . With the information regarding system faults in all MOST control modules, conclusions can be drawn about the cause of the fault. The section below covers the system fault ”Fiber-optic cable, communication fault”. This fault can be entered in all MOST control modules.

Fault memory entry: Fiber-optic cable communication fault

The fault ”Fiber-optic cable communication fault” indicates a problem with the optical transmission. Insufficient light is coming through at one position in the ring. Causes may be:

If the fault is stored, the running system triggers a reset and starts up once again. This switches off music briefly; the screen of the Control Displays continues to run.

If this fault is entered in a control module, it is first of all not possible to determine where the defect lies in the MOST ring. The fault lies between the control module that was first to store the fault ”Fiber-optic cable communication fault” and the control module preceding it in the MOST ring. The following procedure is required to localize the fault:

  1. Starting in MOST ring order (see circuit diagram) with the control module instrument cluster, check whether the ”Fiber-optic cable, communication fault” is stored.
    Note:
    Following the short test, the fault-pattern selection contains the all stored vehicle faults. This enables you to determine quickly which control module was first to store the ”Fiber-optic cable, communication fault”.
    The fault lies between the control module that was first to store the ”Fiber-optic cable communication fault” (= control module B) and the control module preceding it in the MOST ring (= control module A)
  2. In the case of voltage dips below 9 V, it can occur that the fault is stored ”incorrectly”. For this reason, perform the following test as a countercheck:
  3. Check control modules A and B for loose plug-in connections and check the fiber-optic cable for kinks in the wiring harness. If the results of the visual inspection appear to be in order, the fault can only be accurately located (transmit diode control module A, receiver diode control module B, fiber-optic cable) using the optical testing and programming unit. The test program for the optical test on the MOST bus can be found under function selection: Body, Bus Functions, MOST Functions and Optical Test.