Setting the wiper range
The upper reversal position of the windscreen wiper can be set to an accuracy of +/- 5 mm using the service function ”Set wiper range”.
Setting procedure
The upper reversal position is set using the following correction sequence:
- Start of the correction sequence
The wiper is activated via a diagnosis command and moves to the upper reversal position stored in the wiper module. The wipers come to a standstill there.
- Determining the deviation
If it is necessary to correct the upper reversal position, the deviation from the setpoint position is measured using a ruler.
- Entering the correction value
In the test module, the correction value measured in mm is entered. As the value is only transferred to the wiper module in 5-mm steps, it is enough to measure up to an accuracy of 5 mm.
Entering the value
- Transfer into the wiper module
After confirmation of the input, the correction value is transferred to the wiper module.