Specified and substitute values for temperature sensor - IHKA MINI

Data on working range and substitute value in event of cutout or K bus fault.

Temperature sensor

Working range

Substitute value

Heat exchange sensor

-40°C ... 100°C

80°C

Evaporator sensor

-30°C ... 62.456°C

-10°C

Interior temperature sensor

-40°C ... 80°C

25°C

Exterior temperature value

K-bus

-

Coolant temperature value

K-bus

-

Specified temperature

15°C ... 29°C

-

Data on resistance values at an ambient temperature of 25°C and fault limits.

Temperature sensor

Resistance

Tolerance

Heat exchange sensor

10 kOhm

+/- 500 Ohm

Evaporator sensor

5 kOhm

+/- 250 Ohm

Interior temperature

10 kOhm

+/- 500 Ohm