Setpoint values, outside-temperature sensor

 

Setpoint value table

The following table shows the resistance values of the temperature sensor in relation to the temperature.

For evaluation of the sensor, the measured resistance value must be compared with the corresponding operating temperature in the table.

Operating-temperature range of the outside-temperature sensor from -40°C to +80°C

 

-40°C R = 170 000 ohms +/-5000 ohms

-30°C R = 88 000 ohms +/-2000 ohms

-20°C R = 49 000 ohms +/-1000 ohms

-10°C R = 28 000 ohms +/-500 ohms

0°C R = 16 000 ohms +/-500 ohms

+10°C R = 10 000 ohms +/-100 ohms

+20°C R = 6 000 ohms +/-100 ohms

+25°C R = 5 000 ohms +/-80 ohms

+30°C R = 4 000 ohms +/-70 ohms

+40°C R = 2 700 ohms +/-60 ohms

+50°C R = 1 800 ohms +/-50 ohms

+60°C R = 1 200 ohms +/-50 ohms

+70°C R = 900 ohms +/-40 ohms

+80°C R = 600 ohms +/-40 ohms