Test: Image, RGB

 

On-board monitor system with video module

Work through the corresponding test modules in the diagnostic program for the video module in order to check the AF lines:

On-board monitor system without video module

Symptoms: Faults in menu display AND navigation; no menu display.

Instructions:

If measured values are in specified range:

Evaluating results

If on at least one of the 3 lines:

U = 0 V:Replace navigation computer.

U >= 1.4 V:Replace on-board monitor

If on all 3 lines:

1.4 V > U >= 0.5 V:carry out the 3rd check as described in the following

3rd check

Setpoints: