| Pin | Type | Description / Signal type | Connection / Measuring notes |
|---|
| 1 | A | Supply, MI-bus motors | Stepper motors |
| | | |
| 2 | E | Ground, MI-bus motors | Stepper motors |
| | | |
| 3 | E/A | MI-bus | Stepper motors |
| | | |
| 4 | A | Blower control voltage | Blower output stage |
| | | |
| 5 | | Not used | |
| | | |
| 6 | | Not used | |
| | | |
| 7 | E | Signal inputs | Microswitch, air distribution |
| | | |
| 8 | M | Sensor ground, air conditioning system | Microswitch, air distribution |
| | | |
| 9 | | Not used | |
| | | |
| 10 | | Not used | |
| | | |
| 11 | | Not used | |
| | | |
| 12 | | Not used | |
| | | |
| 13 | A | Signal, fresh air/recirculating air flap actuator | Fresh air/air recirculation flap motor |
| | | |
| 14 | M | Ground signal, fresh air/recirculating air flap actuator | Fresh air/air recirculation flap motor |
| | | |
| 15 | A | Signal, fresh air/recirculating air flap actuator | Fresh air/air recirculation flap motor |
| | | |
| 16 | M | Ground signal, fresh air/recirculating air flap actuator | Fresh air/air recirculation flap motor |
| | | |
| 17 | | Not used | |
| | | |
| 18 | | Not used | |
| | | |